Why Temperature and Humidity Calibration Matters for Thai Food and Pharma
In food processing, pharmaceutical manufacturing, cosmetics, and cold-chain logistics, temperature and humidity control is a regulatory requirement — not just a best practice. Dataloggers and sensors that drift out of specification can silently record incorrect data, leading to:
- Product spoilage or degradation that goes undetected because the sensor reported a safe temperature
- GMP audit failures when regulators ask for calibration certificates and find none
- Import rejections by overseas buyers who require full measurement traceability documentation
Applicable Standards and Regulations in Thailand
- GMP CODEX (FDA Thailand): Requires all measurement devices in the production process to be calibrated on a defined schedule
- PIC/S GMP (pharmaceutical): Thai pharma exporters must comply with PIC/S, which requires calibration and validation of all monitoring instruments in production and storage areas
- WHO Cold Chain guidelines: Vaccines and temperature-sensitive drugs require calibrated sensors with continuous data logging
- FSSC 22000 / ISO 22000: Food safety management systems require monitoring equipment to be calibrated and traceable
Calibration vs Temperature Mapping: What's the Difference?
- Calibration: Verifies that each individual sensor reads accurately against a NIMT-traceable reference standard at multiple set points
- Temperature Mapping (Validation): Proves that an entire storage space — a cold room, incubator, or transport container — maintains uniform temperature throughout its volume under real operating conditions
The correct sequence: calibrate sensors first → use those calibrated sensors to map the space. Using uncalibrated sensors in a mapping exercise invalidates the mapping results.
What Gets Calibrated in a Temperature/Humidity Datalogger
- Temperature sensor: Multiple set points e.g., 2°C, 5°C, 25°C, 30°C depending on the operating range
- Relative humidity sensor: Typically at 30%, 50%, 75%, and 85% RH using a salt bath or reference humidity generator
- Response time: Some standards require verification that the sensor responds fast enough to detect excursions
Calibration Frequency Recommendations
- Every 12 months: Standard GMP requirement for non-CCP dataloggers
- Every 6 months: For sensors at Critical Control Points (CCPs) or in vaccine storage
- Before and after Temperature Mapping: All sensors used in a mapping exercise must be calibrated before the test begins
Finding Thai Labs Accredited for Temperature and Humidity Calibration
ThaiLabHub lists ISO 17025-accredited labs with Temperature and Humidity Measurement scope across Thailand. Search by province and scope to find the right lab for your GMP compliance needs.
Frequently Asked Questions
Datalogger ต้องสอบเทียบบ่อยแค่ไหนสำหรับโรงงานอาหาร GMP?▾
GMP ไทย (GMP CODEX) และ FDA 21 CFR กำหนดให้สอบเทียบเครื่องมือวัดอย่างน้อยปีละหนึ่งครั้ง หรือตามคำแนะนำผู้ผลิต แต่สำหรับ datalogger ที่ใช้ใน critical control point (CCP) บางองค์กรเลือกสอบเทียบทุก 6 เดือนเพื่อความปลอดภัยเพิ่มเติม
Calibration กับ Validation ของห้อง Cold Room ต่างกันอย่างไร?▾
Calibration คือการตรวจสอบความแม่นยำของ sensor แต่ละตัวเทียบกับ reference ที่สอบกลับได้ ส่วน Validation (เช่น Temperature Mapping) คือการพิสูจน์ว่าห้องทั้งห้องรักษาอุณหภูมิในขอบเขตที่กำหนดได้อย่างสม่ำเสมอ ทั้งสองอย่างมักทำคู่กัน: สอบเทียบ sensor ก่อน แล้วจึง map ห้อง
Datalogger ยี่ห้อไหนต้องสอบเทียบ? ทุกยี่ห้อเหมือนกันไหม?▾